Description
450mm diameter polypropylene inspection chamber for adoptable and non-adoptable applications. Compliant with Sewers for Adoption 7th edition [SfA7].
Choice of eight bases for equal and unequal pipe connections.
Dedicated bases for use directly with either 110/160mm plastic pipework or 150mm UltraRib system via the appropriate adaptor (6UR141).
450mm diameter shaft may be cut to length to achieve required invert up to maximum 3 metres.
Applications
- For above ground access and maintenance inspection of buried pipework up to 3 metres deep
- For loading applications:
- A15 (1.5 tonnes)
- B125 (12.5 tonnes) *
- D400 (40 tonnes) *
* With cover & frame supported by concrete plinth
NOTE: Concrete plinth not required for non-loaded applications such as domestic gardens
Key Dimensions
- Invert depth of bases: 440-462mm (at centre point of base)
- External shaft diameter: 515mm
- Shaft length: 3m
- Maximum installation depth: 3m
Key Features & Benefits
- Full range of dedicated bases, ensure that smooth flow can be achieved
- Quick & easy to install, with a sculpturedneck on the base,
- which allows the shaft to be fitted with little effort
- Lightweight polypropylene chamber bases, no lifting equipment required
- 3m shaft can be cut to required length
Compliance
Range 450 chambers comply with the following standards and regulations
- BS EN 13598-2: 2009
- SfA7 Typical Chamber Detail – Type 3: (Non-entry. Maximum depth from cover level to soffit of pipe: 3m)
- Building Regulations – Part H1: Shallow and/or Deep