Product Details: 

Description

250mm diameter polypropylene inspection chamber for adoptable and non-adoptable applications. Compliant with Sewers for Adoption 7th edition [SfA7].

Single unit with integral shaft, for use with 110mm OsmaDrain system.

Shaft may be cut to length to achieve required invert depth.

Applications

  • For above ground access and maintenance inspection of buried pipework up to 0.6 metres deep
  • For loading applications up to 15kN (1.5 Tonne)

Key Dimensions

  • External shaft diameter: 250mm
  • Inlets/outlets: 110mm

Key Features & Benefits

  • Fast, easy installation: no wet trades
  • Lightweight: no lifting equipment required
  • Shaft can be cut to required length
  • No additional trench excavation required

Compliance

  • The Shallow Inspection Chamber complies with the following standards and regulations BS EN 13598-1: 2010
  • SfA7 Typical Chamber Detail – Type 4: (to max. 0.6m depth only)
  • Building Regulations – Part H1: Shallow only, to maximum depth 0.6m
Product Image: 

Wavin is part of Orbia, a community of companies working together to tackle some of the world's most complex challenges. We are bound by a common purpose: To Advance Life Around the World.

Please Wait