Product Details: 

Description

315mm diameter polypropylene inspection chamber for adoptable and non-adoptable applications. Compliant with Sewers for Adoption 7th edition [SfA7].

Choice of ten base configurations for use with 110mm OsmaDrain system.

Shaft may be assembled to required invert depth by using shaft sections 4D937.

Applications

  • For above ground access and maintenance inspection of buried pipework
    • Down to 0.6m deep under Building Regulations – Part H1
    • Down to 0.9m deep under SfA7 Typical Chamber Detail – Type 4
  • For loading applications up to 15kN (1.5 Tonne)

Key Dimensions

  • Invert depth of base: 205mm
  • External shaft diameter: 315mm
  • Shaft section length: 150mm
  • Inlets/outlets: 110mm

Key Features & Benefits

  • Multiple options for maximum installation flexibility
  • Fast, easy installation: no wet trades
  • Lightweight: no lifting equipment required
  • Push-fit shaft sections: one or more can be used to achieve required invert depth
  • Final shaft section can be cut to required length
  • No additional trench excavation required

Compliance

Multi-Base Inspection Chambers comply with the following standards and regulations

  • BS EN 13598-1: 2010 a
  • SfA7 Typical Chamber Detail – Type 4 (to max. 0.9m depth only)
  • Building Regulations – Part H1: Shallow only, to maximum depth 0.6m