Product Details:
Description
315mm diameter polypropylene inspection chamber for adoptable and non-adoptable applications. Compliant with Sewers for Adoption 7th edition [SfA7].
Choice of ten base configurations for use with 110mm OsmaDrain system.
Shaft may be assembled to required invert depth by using shaft sections 4D937.
Applications
- For above ground access and maintenance inspection of buried pipework
- Down to 0.6m deep under Building Regulations – Part H1
- Down to 0.9m deep under SfA7 Typical Chamber Detail – Type 4
- For loading applications up to 15kN (1.5 Tonne)
Key Dimensions
- Invert depth of base: 205mm
- External shaft diameter: 315mm
- Shaft section length: 150mm
- Inlets/outlets: 110mm
Key Features & Benefits
- Multiple options for maximum installation flexibility
- Fast, easy installation: no wet trades
- Lightweight: no lifting equipment required
- Push-fit shaft sections: one or more can be used to achieve required invert depth
- Final shaft section can be cut to required length
- No additional trench excavation required
Compliance
Multi-Base Inspection Chambers comply with the following standards and regulations
- BS EN 13598-1: 2010 a
- SfA7 Typical Chamber Detail – Type 4 (to max. 0.9m depth only)
- Building Regulations – Part H1: Shallow only, to maximum depth 0.6m
Product Image: